Open-burner-MAGH80T36-6

Features

● Open burner and oven burner made of cast iron
● Flame supervisory device for safety
● Grates/Trivets made heavy duty cast iron, flame shaping center for efficient heat transfer
● Stainless steel drip tray
● High grade stainless steel: SUS 304 for food contact safety
● Heavy gauge design: 2.0 mm table top; other structural area from 1.2mm to 2.0 mm
● 6” adjustable leg

Gas inlet pressure:
● Natural Gas : 2.0 kPa
● LP Gas : 2.8 kPa
● Town Gas : 1.5 kPa
Gas inlet : DN20

Description

Model Description Dimensions (mm) Gas power
MAGH80T12-2 2 Open burner on cabinet 318 x 800 x (850 + 150) Open burner: 31,000 btu/h (9 kw) x 2
MAGH80T24-4 4 Open burner on cabinet 618 x 800 x (850 +150) Open burner: 31,000 btu/h (9 kW) x 4
MAGH80T36-6 6 Open burner on cabinet 918 x 800 x (850 +150) Open burner: 31,000 btu/h (9 kW) x 6
MAGH80T24-2-12G 2 Open burner +12″griddle on cabinet 618 x 800 x (850 +150) Open burmer: 31,000 btu/h (9 kw) x 2;
Griddle:17,100 btu/h (5 kw)
MAGH80T36-4-12G 4 Open burner +12″griddle on cabinet 918 x 800 x (850 +150) Open burner: 31,000 btu/h (9 kW) x 4 ;
Griddle:17,100 btu/h (5 kw)
MAGH80T36-2-24G 2 Open burner +24″griddle on cabinet 918 x 800 x (850 +150) Open burner: 31,000 btu/h (9 kW) x 2 ;
Griddle:17,100 btu/h (5 kw) x 2
MAGH80T24-4T 4 Open burner, counter top 618 x 800 x (330 + 150) Open burner: 31,000 btu/h (9 kW) x 4
MAGH80T36-6T 6 Open burner, counter top 918 x 800 x (330 + 150) Open burner: 31,000 btu/h (9 kW) x 6


From the blog

Our latest posts

  • Isolate Power & Gas Before Servicing Commercial Gas Equipment

    Isolating power and gas is the first, most important step before cleaning burners, opening a gas train, or touching any ignition components. Done right, it prevents unexpected ignition, fuel release, shock, and equipment damage. This post gives technicians a precise, repeatable procedure you can embed in your SOPs. What “Isolate Power/Gas” Means Why both? Many

    Read more

  • Gas Pressure 101: Static vs. Dynamic — Which Reading Actually Matters?

    Set by dynamic, confirm with static: use dynamic pressure under load for manifold and inlet specs, and use static only to ensure you’re below the max. A quick field procedure and cues help you commission gas equipment right the first time.

    Read more

  • Reducing exhaust to improve yellow or lazy flame

    Why reducing exhaust can help (in some cases) Think of the kitchen as an air-balance equation: Exhaust (out) – Make-Up Air (in) = Pressure deficit (ΔP). In short: you’re not “adding oxygen” by reducing exhaust — you’re removing excessive suction so the oxygen already being supplied can actually reach the burners without being whisked away

    Read more