Steam-Cabinet-BGS-1R

Features

● State of the art technology design
The small fire is equipped with anti-strong airflow and
anti- strong wind technology, which can ensure that it
will not be extinguished in a closed combustion chamber.
Swivel water tank design, no need for blower, water
shortage protection, automatic water filling, and heat
recovery system. Food grade door gasket. Multi-layers
steam tray can steam different type of food at each layer
at the same time.
● Environmentally friendly (High efficiency, low noise
and low CO in exhaust gas)
The thermal efficiency can be up to 90%+. An energy cost
saving up to 50%+. The noise level is less than 60 Db.
The carbon monoxide in flue gas in less than 0.05%.
● Simple operation and safety protection
The flame failure device cuts out gas supply in less than
2 seconds to prevent gas leakage when the flame is notdetected

● Water Inlet:DN15
● Gas inlet: DN25
● Drain outlet: DN25<table align=”center”>
<tbody>
<tr>
<th bgcolor=”#CCCCCC”>Model</th>
<th bgcolor=”#CCCCCC”># of Shelf</th>
<th bgcolor=”#CCCCCC”>Dimensions (mm)</th>
<th bgcolor=”#CCCCCC”>Gas power</th>
</tr>
<tr>
<td align=”center” valign=”middle”>BGS-1VD</td>
<td align=”center” valign=”middle”>10</td>
<td align=”center” valign=”middle”>900 x 950 x 1850</td>
<td align=”center” valign=”middle”>71700 btu/h (21 kW)</td>
</tr>
<tr>
<td align=”center” valign=”middle”>BGS-2VD</td>
<td align=”center” valign=”middle”>20</td>
<td align=”center” valign=”middle”>1200 x 950 x 1850</td>
<td align=”center” valign=”middle”>95600 btu/h (28 kW)</td>
</tr>
</tbody>
</table>

Category:

Description

 

Model GN size & Qty Dimensions (mm) Gas power
BGS-1R GN 2/1, 13 pcs 1300 x 950 x 1850 95600 btu/h (28 kW)

From the blog

Our latest posts

  • Isolate Power & Gas Before Servicing Commercial Gas Equipment

    Isolating power and gas is the first, most important step before cleaning burners, opening a gas train, or touching any ignition components. Done right, it prevents unexpected ignition, fuel release, shock, and equipment damage. This post gives technicians a precise, repeatable procedure you can embed in your SOPs. What “Isolate Power/Gas” Means Why both? Many

    Read more

  • Gas Pressure 101: Static vs. Dynamic — Which Reading Actually Matters?

    Set by dynamic, confirm with static: use dynamic pressure under load for manifold and inlet specs, and use static only to ensure you’re below the max. A quick field procedure and cues help you commission gas equipment right the first time.

    Read more

  • Reducing exhaust to improve yellow or lazy flame

    Why reducing exhaust can help (in some cases) Think of the kitchen as an air-balance equation: Exhaust (out) – Make-Up Air (in) = Pressure deficit (ΔP). In short: you’re not “adding oxygen” by reducing exhaust — you’re removing excessive suction so the oxygen already being supplied can actually reach the burners without being whisked away

    Read more