Tier Shelf

Superior strength
● As strong as welded construction, meeting rigorous load
bearing test and impact test.
● Do away with weak weldment as commonly seen due to
poor workmanship
Flat pack (knock down) design
● For low cost of transportation and storage.
● Easy and quick to install.

Dimensions
● Standard widths (mm): 1000, 1200, 1500,
1800 (other widths available)
● Standard depths (mm): 600, 800 (700 also
available)
● Overall height (mm): 1500 mm (4 tier),
1800 mm (5 tier)
Feel free to contact us should you have
dimensional requirement other than the above.

Category:

Description

Model below are of material 304. Please contact us if you need 201.

 

Item Number of Tier Type of shelf Width Depth
CJP1050-2 4 flat 1000 500
CJP1250-2 4 flat 1200 500
CJP1550-2 4 flat 1500 500
CJP1850-2 4 flat 1800 500
CJP1050-3 5 flat 1000 500
CJP1250-3 5 flat 1200 500
CJP1550-3 5 flat 1500 500
CJP1850-3 5 flat 1800 500
CJC1050-2 4 Slat (flat) 1000 500
CJC1250-2 4 Slat (flat) 1200 500
CJC1550-2 4 Slat (flat) 1500 500
CJC1850-2 4 Slat (flat) 1800 500
CJC1050-3 5 Slat (flat) 1000 500
CJC1250-3 5 Slat (flat) 1200 500
CJC1550-3 5 Slat (flat) 1500 500
CJC1850-3 5 Slat (flat) 1800 500
CJS1050-2 4 Slat (tube) 1000 500
CJS1250-2 4 Slat (tube) 1200 500
CJS1550-2 4 Slat (tube) 1500 500
CJS1850-2 4 Slat (tube) 1800 500
CJS1050-3 5 Slat (tube) 1000 500
CJS1250-3 5 Slat (tube) 1200 500
CJS1550-3 5 Slat (tube) 1500 500
CJS1850-3 5 Slat (tube) 1800 500

We have plenty of different specifications for your
choice. The above are the more commonly used
construction. If you do not find the one you need,
please feel free to contact the factory.

Flat Shelf
● Made of AISI 304 (201 option is available)
● Welded frame and corners with satin (Scotch Brite) finishing
● Channel reinforced
● 40 mm high profile
● Thickness: standard 1.2 mm, other thickness also available)
● Come with or without vent holes.
Slatted Shelf
● Frame: 38 x 25 rectangular section
● Inside beam: 25 x 25 square section
Note: Shelf height not adjustable.
Leg:Square section (38 x 38 mm)

From the blog

Our latest posts

  • Isolate Power & Gas Before Servicing Commercial Gas Equipment

    Isolating power and gas is the first, most important step before cleaning burners, opening a gas train, or touching any ignition components. Done right, it prevents unexpected ignition, fuel release, shock, and equipment damage. This post gives technicians a precise, repeatable procedure you can embed in your SOPs. What “Isolate Power/Gas” Means Why both? Many

    Read more

  • Gas Pressure 101: Static vs. Dynamic — Which Reading Actually Matters?

    Set by dynamic, confirm with static: use dynamic pressure under load for manifold and inlet specs, and use static only to ensure you’re below the max. A quick field procedure and cues help you commission gas equipment right the first time.

    Read more

  • Reducing exhaust to improve yellow or lazy flame

    Why reducing exhaust can help (in some cases) Think of the kitchen as an air-balance equation: Exhaust (out) – Make-Up Air (in) = Pressure deficit (ΔP). In short: you’re not “adding oxygen” by reducing exhaust — you’re removing excessive suction so the oxygen already being supplied can actually reach the burners without being whisked away

    Read more